Vista de pagina 0
PRECISION DIGITAL CORPORATION
89 October Hill Road • Holliston MA 01746 USA
Tel (800) 343-1001 • Fax (508) 655-8990
www.predig.com
PD6830 EXPLOSION-PROOF
PULSE INPUT RATE/TOTALIZER
Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave
(Coil), Square Wave, Opto-Isolated Inputs
Explosion-Proof, IP68, NEMA 4X Enclosure
Isolated 4-20 mA Output for Rate, Total, or Grand Total
5-Digit 0.7" (17.8 mm)Top Display for Rate or Total
7 Alphanumeric Character 0.4" (10.2 mm) Bottom Display for Rate,
Total, Grand Total, Units, and Tag
13-Digit Totalizer with Total Overflow Feature
SafeTouch
®
Through-Glass Button Programming
Battery, DC, or Output Loop-Powered Models
Two Isolated Open Collector Pulse Outputs, Up to 5 kHz
Automatic Rate, Total, & Grand Total Unit Conversions
Gate Function for Rate Display of Slow Pulse Rates
K-Factor, Scaling, or Live Input Calibration with 32-Point Linearization
Password Protection
Backlight Standard on All Models
Operates from -40 to 75°C
Data Logging Functions and Modbus
®
Accessible Data
Vista de pagina 0
1 2 3 4 5 6 ... 99 100

Indice de contenidos

Pagina 1 - PULSE INPUT RATE/TOTALIZER

PRECISION DIGITAL CORPORATION 89 October Hill Road • Holliston MA 01746 USA Tel (800) 343-1001 • Fax (508) 655-8990 www.predig.com PD6830 EXPLOSION-PR

Pagina 2

PD6830 Pulse Input Rate/Totalizer Instruction Manual 10 OPTO-ISOLATED IN-PUT Sourcing pulse or square wave 0-5 V, 0-12 V, or 0-24 V; Logic High: 2-24

Pagina 3 - ORDERING INFORMATION

PD6830 Pulse Input Rate/Totalizer Instruction Manual LIM6830_K SFT050 Ver 3.200 & up 03/15 How to Contact Precision Digital  For Technical Suppo

Pagina 4 - Table of Contents

PD6830 Pulse Input Rate/Totalizer Instruction Manual 11 Rate/Totalizer DISPLAY ASSIGNMENT The Top display is assigned to rate or total. The Bottom d

Pagina 5

PD6830 Pulse Input Rate/Totalizer Instruction Manual 12 TOTAL OVERFLOW AND ROLLOVER The total can display up to 9,999,999,999,999. Up to 9,999,999 can

Pagina 6 - Table of Figures

PD6830 Pulse Input Rate/Totalizer Instruction Manual 13 4-20 mA Transmitter Output OUTPUT SOURCE Rate/process, total, grand total, or disabled SCALIN

Pagina 7 - SPECIFICATIONS

PD6830 Pulse Input Rate/Totalizer Instruction Manual 14 PULSE OUTPUT K-FACTOR (COUNT) K-factor (couNT) programmable from 0.000001 to 9999999. Rate pul

Pagina 8

PD6830 Pulse Input Rate/Totalizer Instruction Manual 15 Product Ratings and Approvals FM Class I, Division 1, Groups B, C, D Class II, Division 1,

Pagina 9 - Rate Input

PD6830 Pulse Input Rate/Totalizer Instruction Manual 16 Electromagnetic Compatibility EMISSIONS EN 61326:2006 Safety requirements for measurement, con

Pagina 10

PD6830 Pulse Input Rate/Totalizer Instruction Manual 17 INSTALLATION For Installation in USA: The PD6830 must be installed in accordance with the Nati

Pagina 11 - Rate/Totalizer

PD6830 Pulse Input Rate/Totalizer Instruction Manual 18 Mounting The PD6830 has two slotted mounting flanges that may be used for pipe mounting or wal

Pagina 12

PD6830 Pulse Input Rate/Totalizer Instruction Manual 19 Connections (continued) S+ Signal input positive terminal connection S- Signal input negativ

Pagina 13 - Open Collector Outputs

PD6830 Pulse Input Rate/Totalizer Instruction Manual 2 Disclaimer The information contained in this document is subject to change without notice. Prec

Pagina 14 - Serial Communications

PD6830 Pulse Input Rate/Totalizer Instruction Manual 20 Input Signal Connections Signal connections are made to a barrier terminal mounted in the base

Pagina 15 - II 2 GD

PD6830 Pulse Input Rate/Totalizer Instruction Manual 21 Figure 5. NPN Open Collector Input (NPN) Figure 6. PNP Sensor with External Power (PNP)

Pagina 16 - SAFETY INFORMATION

PD6830 Pulse Input Rate/Totalizer Instruction Manual 22 DC Power Connection Models configured for DC power (PD6830-A) are provided with a terminal lab

Pagina 17 - INSTALLATION

PD6830 Pulse Input Rate/Totalizer Instruction Manual 23 4-20 mA Transmitter Output Connections Output connections are made to two terminals labeled LP

Pagina 18 - Connections

PD6830 Pulse Input Rate/Totalizer Instruction Manual 24 Open Collector Output Connections Open collector output 1 and 2 connections are made to termin

Pagina 19 - Connections (continued)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 25 Battery Replacement Battery-equipped models have a battery charge monitor. When the battery i

Pagina 20 - Input Signal Connections

PD6830 Pulse Input Rate/Totalizer Instruction Manual 26 SETUP AND PROGRAMMING There is no need to recalibrate the meter for frequency in Hz when fir

Pagina 21

PD6830 Pulse Input Rate/Totalizer Instruction Manual 27 SafeTouch® Button Tips and Troubleshooting The SafeTouch Buttons are designed to filter normal

Pagina 22 - DC Power Connection

PD6830 Pulse Input Rate/Totalizer Instruction Manual 28 Buttons and Display ENTERDISPLAYRESETMENU Button Symbol Description Symbol Status Menu/ Safe

Pagina 23 - 4-20 mA Input

PD6830 Pulse Input Rate/Totalizer Instruction Manual 29 Menu Button  Hold the Menu SafeTouch® button when in power save mode (display will show ) to

Pagina 24

PD6830 Pulse Input Rate/Totalizer Instruction Manual 3 INTRODUCTION The ProtEX-RTP PD6830 is a rugged, explosion-proof, pulse input rate/totalizer for

Pagina 25 - Battery Replacement

PD6830 Pulse Input Rate/Totalizer Instruction Manual 30 Setting Numeric Values The numeric values are set using the Right and Up arrow buttons. Press

Pagina 26 - SETUP AND PROGRAMMING

PD6830 Pulse Input Rate/Totalizer Instruction Manual 31 Main Menu The main menu separates the most commonly used functions in the Setup menu, and mor

Pagina 27 - SafeTouch

PD6830 Pulse Input Rate/Totalizer Instruction Manual 32 Setup Menu Display Functions & Messages The meter displays various functions and messages

Pagina 28 - DISPLAY

PD6830 Pulse Input Rate/Totalizer Instruction Manual 33 Display Parameter Action/Setting P/HECtL Pulses/hectoliter Set K-factor in pulses per hectoli

Pagina 29

PD6830 Pulse Input Rate/Totalizer Instruction Manual 34 Display Parameter Action/Setting CHAR Character Set a character in a custom unit label ratCF

Pagina 30 - Setting Numeric Values

PD6830 Pulse Input Rate/Totalizer Instruction Manual 35 Display Parameter Action/Setting TOTAL+U````````````````` Total & units Display total and

Pagina 31 - Main Menu

PD6830 Pulse Input Rate/Totalizer Instruction Manual 36 Setting Up the Meter (SETUP) The Setup menu is used to select: 1. Input type selection (INPuT

Pagina 32

PD6830 Pulse Input Rate/Totalizer Instruction Manual 37 Selecting Input Type (Input) Seven input types may be set. See Rate Input specifications on pa

Pagina 33

PD6830 Pulse Input Rate/Totalizer Instruction Manual 38

Pagina 34

PD6830 Pulse Input Rate/Totalizer Instruction Manual 39 Entering the K-Factor (Factr) The meter may be scaled using the K-factor, or conversion facto

Pagina 35

PD6830 Pulse Input Rate/Totalizer Instruction Manual 4 Table of Contents INTRODUCTION ----------------------------------------------------------------

Pagina 36 - Setting Up the Meter (SETUP)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 40 K-Factor Value (factr) Enter the K-factor value. This value is entered in Pulses/Unit as defin

Pagina 37 - INPUT LEVEL

PD6830 Pulse Input Rate/Totalizer Instruction Manual 41 The following units may be selected as the base units for rate, total, and grand total. Time

Pagina 38 -

PD6830 Pulse Input Rate/Totalizer Instruction Manual 42 Setting the Time Base (tbase) The meter calculates rate based on rate time base and rate displ

Pagina 39 - K-Factor Units (FuNiT)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 43 Setting the Rate Display Units (rateU) Rate is displayed in terms of a unit of volume, and a t

Pagina 40 - Display Units (Units)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 44 Total Units (tot U) This menu is used to select the display units for the total. The base unit

Pagina 41

PD6830 Pulse Input Rate/Totalizer Instruction Manual 45 Grand Total Units (GtotU) This menu is used to select the display units for the grand total. T

Pagina 42

PD6830 Pulse Input Rate/Totalizer Instruction Manual 46 Automatic Unit Conversions When switching from any standard unit of rate, total, or grand tota

Pagina 43

PD6830 Pulse Input Rate/Totalizer Instruction Manual 47 Rate Conversion Factor is used to convert to a custom unit of rate display. For example, to di

Pagina 44 - Total Units (tot U)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 48 Setting the Decimal Point (dec.PT) Rate decimal point may be set with up to four decimal place

Pagina 45 - Grand Total Units (GtotU)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 49 Configuring the Display (Dsply) The top and bottom displays can be independently programmed to

Pagina 46 - Custom Units Entry (USER)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 5 Total Units (tot U) ------------------------------------------------------------------------- 4

Pagina 47

PD6830 Pulse Input Rate/Totalizer Instruction Manual 50 Bottom Display (bOtm) The bottom display can be programmed to display the following informatio

Pagina 48

PD6830 Pulse Input Rate/Totalizer Instruction Manual 51 Custom Tag (TAG) When the bottom display selected includes a custom tag, a User menu will then

Pagina 49 - Top Display (TOp)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 52 Setting the Toggle Time (TIME) If the bottom display is programmed to toggle (TOGLE), the mete

Pagina 50 - Bottom Display (bOtm)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 53 Advanced Features Menu To simplify the setup process, functions not needed for most applicatio

Pagina 51 - Custom Tag (TAG)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 54 Advanced menus A OUT displayed only for meters with the analog output option, COMM displaye

Pagina 52

PD6830 Pulse Input Rate/Totalizer Instruction Manual 55 Advanced Features Menu & Display Messages The following table shows the Advanced features

Pagina 53 - Advanced Features Menu

PD6830 Pulse Input Rate/Totalizer Instruction Manual 56 Display Parameter Action/Setting OUt 1 Output 1 Output 1 value Dsp 2 Display 2 Output display

Pagina 54

PD6830 Pulse Input Rate/Totalizer Instruction Manual 57 Display Parameter Action/Setting T DELAY Time delay Automatic reset time delay time Total Res

Pagina 55

PD6830 Pulse Input Rate/Totalizer Instruction Manual 58 Display Parameter Action/Setting LOGTIME Log time Set daily data log times LOG 1 Log 1 Set fi

Pagina 56

PD6830 Pulse Input Rate/Totalizer Instruction Manual 59 Open Collector Outputs (OUTPUT) The meter is equipped with two NPN open collector outputs that

Pagina 57

PD6830 Pulse Input Rate/Totalizer Instruction Manual 6 Wakeup the Meter (WAKEUP?) ----------------------------------------------------------- 87OPERA

Pagina 58

PD6830 Pulse Input Rate/Totalizer Instruction Manual 60 Output 1 and 2 Setup (OUT 1, OUT 2) The function of open collector output 1 and 2 is configure

Pagina 59

PD6830 Pulse Input Rate/Totalizer Instruction Manual 61 Total & Grand Total Pulse Output (Total, Grtot) A total and grand total based pulse output

Pagina 60 - Pulse Output (PUlse)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 62 Alarm Output (alrm) Alarm outputs may be assigned to rate, total, or grand total; or be forced

Pagina 61

PD6830 Pulse Input Rate/Totalizer Instruction Manual 63 If automatic total/grand total reset is enabled, the output will generate an alarm for a perio

Pagina 62 - Alarm Output (alrm)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 64 Scaling the 4-20 mA Analog Output (Aout) The Analog Output menu is used to program the 4-20 m

Pagina 63 - Total Reset Output (t rst)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 65 Gate Function (GATE) The gate function is used for displaying slow pulse rates. Using the prog

Pagina 64

PD6830 Pulse Input Rate/Totalizer Instruction Manual 66 Scaling & Calibration (SCALCAL) It is very important to read the following information, b

Pagina 65 - Low-Flow Cutoff (CUTOFF)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 67 Scaling the Meter (SCale) The pulse input can be scaled to display the process variable in eng

Pagina 66

PD6830 Pulse Input Rate/Totalizer Instruction Manual 68 Multi-Point Linearization (nopts) Up to 32 linearization points can be selected under the nopt

Pagina 67 - Scaling the Meter (SCale)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 69 Calibrating the Meter (CaL) To scale the meter without a signal source refer to Entering the K

Pagina 68

PD6830 Pulse Input Rate/Totalizer Instruction Manual 7 SPECIFICATIONS Except where noted all specifications apply to operation at +25°C. General DISPL

Pagina 69 - Calibrating the Meter (CaL)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 70 The multi-point linearization feature (nopts) can be used to linearize the display for non-lin

Pagina 70

PD6830 Pulse Input Rate/Totalizer Instruction Manual 71 Error Message (Error) An error message indicates that the calibration or scaling process was

Pagina 71 - Total Reset (T Reset)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 72 Manual or Automatic Total Reset Function (t rST) For manual reset, select T RESET  t rst  ma

Pagina 72 - Total Alarm Time

PD6830 Pulse Input Rate/Totalizer Instruction Manual 73 Manual or Automatic Grand Total Reset Function (GtrST) For manual reset, select T RESET  Gtrs

Pagina 73 - Grand Total Alarm Time

PD6830 Pulse Input Rate/Totalizer Instruction Manual 74 Setting Up Passwords (PASSWRD) The Password menu is used to program a five-digit password to p

Pagina 74

PD6830 Pulse Input Rate/Totalizer Instruction Manual 75 Resetting Total & Grand Total on a Password Protected Meter If the meter is password prote

Pagina 75

PD6830 Pulse Input Rate/Totalizer Instruction Manual 76 To configure the meter for non-resettable grand total mode, enter the non-resettable grand to

Pagina 76

PD6830 Pulse Input Rate/Totalizer Instruction Manual 77 Custom (CUSTOM) The Custom menu is used to modify the initial programming menus that appear i

Pagina 77 - Custom (CUSTOM)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 78 Custom Menu Parameters Display Parameter/Menu Action NONE None Set no menu position display I

Pagina 78

PD6830 Pulse Input Rate/Totalizer Instruction Manual 79 LOGTIME Log Time Set daily data log times INTERVL Interval Set interval log times LOGVIEW Log

Pagina 79 - System (SYSTEM)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 8 PASSWORD MENU OPTIONS Three programmable password selections can be used for the following: res

Pagina 80

PD6830 Pulse Input Rate/Totalizer Instruction Manual 80 Set Real Time Clock (SETTIME) The real time clock is used to trigger data log events, and is

Pagina 81 - Data Log Setup (DATALOG)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 81 Data Log Setup (DATALOG) The Data Log menu is used to setup and enable the data log functions.

Pagina 82 - Interval Setup (INTERVL)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 82 Log Time Setup (LOGTIME) The Log Time menu contains four log points (LOG 1 to LOG 4). Each log

Pagina 83 - Backlight (BAKLITE)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 83 View Data Log (LOGVIEW) The Log View menu allows on-screen browsing of the data log points sto

Pagina 84

PD6830 Pulse Input Rate/Totalizer Instruction Manual 84 Backup & Restore (BACKUP) The features are used to save and restore programmed settings.

Pagina 85 - Information (INFO)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 85 Battery Power Symbol Alert (BAT SYM) The Battery Power Symbol Alert menu is used to enable or

Pagina 86 - Serial Communications (COMM)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 86 Serial Communications (COMM) The Communications menu is used to setup serial communications pa

Pagina 87 - Standby Mode (STANDBY)

PD6830 Pulse Input Rate/Totalizer Instruction Manual 87 Standby Mode (STANDBY) Standby mode is available on battery powered and battery backup models

Pagina 88 - OPERATION

PD6830 Pulse Input Rate/Totalizer Instruction Manual 88 OPERATION Front Panel Buttons Operation Symbol Description  Hold the Menu SafeTouch® button

Pagina 89 - SafeTouch Button Operation

PD6830 Pulse Input Rate/Totalizer Instruction Manual 89 The following SafeTouch button information is reprinted from SafeTouch Button Operation on pa

Pagina 90

PD6830 Pulse Input Rate/Totalizer Instruction Manual 9 ISOLATION All Models: 500 V opto-isolated input-to-power/output with isolated input enabled P

Pagina 91

PD6830 Pulse Input Rate/Totalizer Instruction Manual 90 SafeTouch® Button Tips and Troubleshooting The SafeTouch Buttons are designed to filter normal

Pagina 92

PD6830 Pulse Input Rate/Totalizer Instruction Manual 91 Grand Total Reading (GrTOTAL) The grand total is a separate total that is not reset when the t

Pagina 93

PD6830 Pulse Input Rate/Totalizer Instruction Manual 92 Resetting the Total (RESET TOTAL?) If manual Total Reset is enabled in the Program menu, the t

Pagina 94

PD6830 Pulse Input Rate/Totalizer Instruction Manual 93 Factory Defaults & User Settings The following table shows the factory setting for most of

Pagina 95 - TROUBLESHOOTING

PD6830 Pulse Input Rate/Totalizer Instruction Manual 94 Parameter Display Default Setting User SettingScale Enable SCALE No – Use K-Factor Scale/

Pagina 96 - MOUNTING DIMENSIONS

PD6830 Pulse Input Rate/Totalizer Instruction Manual 95 TROUBLESHOOTING The rugged design and the user-friendly interface of the meter should make it

Pagina 97 - 4.86 [123.5]

PD6830 Pulse Input Rate/Totalizer Instruction Manual 96 MOUNTING DIMENSIONS All units: inches [mm] Figure 16. Enclosure Dimensions – Front View

Pagina 98

PD6830 Pulse Input Rate/Totalizer Instruction Manual 97 Figure 17. Enclosure Dimensions – Side Cross Section View 3.35 [85.0]4.15 [105.5]3.22 [81.

Pagina 99 - EC DECLARATION OF CONFORMITY

PD6830 Pulse Input Rate/Totalizer Instruction Manual 98 QUICK USER INTERFACE REFERENCE Pushbutton Function Menu Go to Programming mode, back out one

Pagina 100 - SFT050 Ver 3.200 & up

PD6830 Pulse Input Rate/Totalizer Instruction Manual 99 EC DECLARATION OF CONFORMITY Issued in accordance with ATEX Directive 94/9/EC Manufacture