Strain Gauge, Load Cell & mV Meter
PD6100 Instruction Manual
15, 30, 150, 300 mV Unipolar Input Ranges
±15, ±25, ±150, ±250 mV Bipolar Input Ranges
Selectable 5 or 10 VDC Sensor Excitation
Supports up to Twelve (12) 350 Load Cells
(Minimum Load Resistance of 28 )
Capture or Programmable Tare Feature
Max/Min or Peak/Valley Hold Feature
Ratiometric Operation
Large Dual-Line 6-Digit Display, 0.60" & 0.46"
Dual-Scale Feature – Single Input
Rounding Function 1, 2, 5, 10, 20, 50, or 100
Auto-Zero Feature Eliminates Zero Drift
Programmable Display & Function Keys
32-Point Linearization
NEMA 4X, IP65 Front
Universal 85-265 VAC, or 12/24 VDC Input Power Models
2 or 4 Relays + Isolated 4-20 mA Output Options
External 4-Relay & Digital I/O Expansion Modules
USB, RS-232, & RS-422/485 Serial Communication Options
Modbus
®
RTU Communication Protocol Standard
Configure, Monitor, and Datalog from a PC with
Free MeterView
®
Pro Software
Vista de pagina 0
1 2 3 4 5 6 ... 99 100

Indice de contenidos

Pagina 1 - PD6100 Instruction Manual

PRECISION DIGITAL CORPORATION 89 October Hill Road • Holliston MA 01746 USA Tel (800) 343-1001 • Fax (508) 655-8990 www.predig.com Strain Gauge, Loa

Pagina 2 - Registered Trademarks

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 10 WEIGHT 9.5 oz (269 g) WARRANTY 3 years parts & labor Strain Gauge Input IN

Pagina 3 - Table of Contents

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual LIM6100_B SFT039 Ver 3.200 & up 1/15 How to Contact Precision Digital  For Te

Pagina 4

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 11 DEADBAND 0-100% of span, user programmable HIGH OR LOW ALARM User may program a

Pagina 5

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 12 NON-ISOLATED TRANSMITTER POWER SUPPLY Terminals I+ & R: 24 VDC  10% . May b

Pagina 6 - INTRODUCTION

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 13 Electromagnetic Compatibility EMISSIONS EN 55022:2010 Class A ITE emissions requ

Pagina 7 - ORDERING INFORMATION

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 14 SAFETY INFORMATION CAUTION: Read complete instructions prior to inst

Pagina 8 - SPECIFICATIONS

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 15 Figure 1. 1/8 DIN Panel Cutout Dimensions Figure 2. Panel Mounting Details P

Pagina 9

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 16 Mounting Dimensions Figure 3. Meter Dimensions - Side View Figure 4. Meter

Pagina 10 - Strain Gauge Input

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 17 Configuration for 12 or 24 VDC Input Power Option Warning! Do not exceed volt

Pagina 11

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 18 Sensor Excitation Voltage Selection (EX+, EX-) All meters, including models equi

Pagina 12 - COMPLIANCE INFORMATION

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 19 Connectors Labeling The connectors’ label, affixed to the meter, shows the locat

Pagina 13

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 2 Disclaimer The information contained in this document is subject to change withou

Pagina 14 - INSTALLATION

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 20 Signal Connections Signal connections are made to a six-terminal connector label

Pagina 15 - (1.5mm) Max

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 21 Range (Switch 2) The range switch adjusts the gain of the internal c

Pagina 16 - Mounting Dimensions

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 22 Shunt Resistor (Switch 5) The PD6100 provides a means of simulating s

Pagina 17 - MAIN BOARD

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 23 NOTE: Refer to Switch Configuration starting on page 20 for proper switch positi

Pagina 18 - Connections

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 24 predetermined resistive load(60.4k). This technique can be used as a means of ve

Pagina 19 - Power Connections

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 25 Switching Inductive Loads The use of suppressors (snubbers) is strongly recommen

Pagina 20 - Switch Configuration

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 26 4-20 mA Output Connections Connections for the 4-20 mA transmitter output are ma

Pagina 21

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 27 External Relays & Digital I/O Connections The relay and the digital I/O expa

Pagina 22 - INPUT SIGNAL

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 28 Figure 21. Digital I/O Module Connections Interlock Relay Feature As the name

Pagina 23 - Transducer

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 29 SETUP AND PROGRAMMING The meter is factory calibrated prior to shipment to read

Pagina 24 - RELAY2 RELAY1

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 3 Table of Contents INTRODUCTION --------------------------------------------------

Pagina 25 - Switching Inductive Loads

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 30 Front Panel Buttons and Status LED Indicators Button Symbol Description LED St

Pagina 26 - F4 Digital Input Connections

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 31 Display Functions & Messages The meter displays various functions and messag

Pagina 27 - NO C NO C NO C NO C

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 32 Display Parameter Action/Setting Description Cal Calibrate Enter the Calibration

Pagina 28 - Interlock Relay Feature

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 33 Display Parameter Action/Setting Description RLY 2 Relay 2 Relays 2-8 setup Note

Pagina 29 - SETUP AND PROGRAMMING

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 34 Contrl Control Enter Control menu Auto Automatic Press Enter to set meter for au

Pagina 30

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 35 Main Menu The main menu consists of the most commonly used functions: Setup, Res

Pagina 31

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 36 Setting Up the Meter (setup) The Setup menu is used to select: 1. Unipolar (e.g

Pagina 32

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 37 Setting the Input Signal (Input) Enter the Input menu to set up the input polari

Pagina 33

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 38 Input Polarity Selection (PoLAR) Select unipolar operation for inputs in ranges

Pagina 34 - Setting Numeric Values

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 39 Setting the Input Units (units) Enter the pre-defined engineering unit or custom

Pagina 35 - Main Menu

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 4 Setting Up the Meter (setup) ------------------------------------------------ 36

Pagina 36 - Setting Up the Meter (setup)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 40 Setting the Input Units or Custom Tags (units) Enter the input unit or custom ta

Pagina 37

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 41 Setting the Decimal Point (dEc pt) The decimal point may be set with up to five

Pagina 38

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 42 Programming the Meter (prog) The Program menu contains the Scale and the Calibra

Pagina 39

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 43 Calibrating the Meter with Strain Gauge/Load Cell (Cal) To scale the meter witho

Pagina 40

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 44 MeterView® Pro Software The meter can also be programmed using the PC-based Mete

Pagina 41

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 45 Dual-Scale Application The analog input can be displayed in two different scales

Pagina 42 - Programming the Meter (prog)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 46 Error Message (Error) An error message indicates that the calibration or scaling

Pagina 43

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 47 Setting the Display Parameter & Intensity (dsplay) The upper display (Big) c

Pagina 44

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 48 Display Setup Menu

Pagina 45 - Dual-Scale Application

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 49 Setting the Relay Operation (relay) This menu is used to set up the operation of

Pagina 46 - Minimum Input Span

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 5 Protecting or Locking the Meter ------------------------------------------- 68Ma

Pagina 47

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 50 Setting the Relay Action Operation of the relays is programmed in the Action men

Pagina 48 - Display Setup Menu

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 51 Programming Set and Reset Points High alarm indication: program set point above

Pagina 49

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 52 Relay and Alarm Operation Diagrams The following graphs illustrate the operation

Pagina 50 - Setting the Relay Action

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 53 Low Alarm Operation (Set < Reset) For Manual reset mode, ACK can be pressed

Pagina 51 - Programming Time Delay

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 54 High Alarm with Fail-Safe Operation (Set > Reset) Note: Relay coil is energ

Pagina 52

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 55 Low Alarm with Fail-Safe Operation (Set < Reset) Note: Relay coil is energ

Pagina 53 - Automatic (non-latching)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 56 Pump Alternation Control Operation

Pagina 54

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 57 Relay Sampling Operation When the signal crosses the set point, the relay trip

Pagina 55

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 58 Time Delay Operation The following graphs show the operation of the time delay f

Pagina 56

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 59 Relay Operation Details Overview The relay capabilities of the meter expand its

Pagina 57

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 6 Table of Figures Figure 1. 1/8 DIN Panel Cutout Dimensions ...

Pagina 58 - Time Delay Operation

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 60 Front Panel LEDs The LEDs on the front panel provide status indication for the f

Pagina 59 - Relay Operation Details

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 61 Non-Latching Relay (Auto) Automatic reset only Condition LED RelayNormal Off Off

Pagina 60 - Front Panel LEDs

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 62 Latching Relay (Lt-Clr) Manual reset only after alarm condition has cleared Cond

Pagina 61 - Latching Relay (LatcH)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 63 Pump Alternation Control Applications (Altern) For pump control applications whe

Pagina 62 - Acknowledging Relays

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 64 Application #2: Pump Alternation Using Relays 3 & 4 1. Relays 1 and 2 are s

Pagina 63 - Pump Alternation Operation

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 65 3. If the backup pump is not able to keep up, and the level reaches 7000 gallo

Pagina 64

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 66 Setting Up the Interlock Relay (Force On) Feature Relays 1-4 can be set up as in

Pagina 65

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 67 Scaling the 4-20 mA Analog Output (Aout) The 4-20 mA analog output can be scaled

Pagina 66 - 5 VDC GND

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 68 Setting Up the Password (pass) The Password menu is used for programming three l

Pagina 67 - Setting Numeric

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 69 Making Changes to a Password Protected Meter If the meter is password protected,

Pagina 68

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 7 ORDERING INFORMATION Standard Models 85-265 VAC Model 12/24 VDC Model Options Ins

Pagina 69

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 70 Reset Menu (reset) The Reset menu is used to reset the tare (rst tr) and the max

Pagina 70 - Tare Menu (Tare)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 71 Control Menu (Contrl) The Control menu is used to control the 4-20 mA analog out

Pagina 71 - Advanced Features Menu

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 72 Advanced Features Menu & Display Messages The following table shows the func

Pagina 72

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 73 Display Parameter Action/Setting O-rang Overrange Program mA output for display

Pagina 73

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 74 Display Parameter Action/Setting v Hi mV high Calibrate high mV input (e.g. 10

Pagina 74

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 75 Noise Filter (filter) The noise filter is available for unusually noisy signals

Pagina 75 - Rounding Feature (round)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 76 Modbus RTU Serial Communications (serial) The meter is equipped with serial comm

Pagina 76

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 77 Select Menu (SElect) The Select menu is used to select the signal input conditio

Pagina 77 - Select Menu (SElect)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 78 Multi-Point Linearization (Linear) Meters are set up at the factory for linear f

Pagina 78 - Auto-Zero (Auto 0)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 79 Low-Flow Cutoff (CutofF) The low-flow cutoff feature allows the meter to be prog

Pagina 79 - Low-Flow Cutoff (CutofF)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 8 SPECIFICATIONS Except where noted all specifications apply to operation at +25°C.

Pagina 80

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 80 Programmable Function Keys User Menu (user) The User menu allows the user to ass

Pagina 81

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 81 Internal Source Calibration (ICAL) The meter is factory calibrated prior to ship

Pagina 82

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 82 Example of Internal Calibration for 100 mV input range: 4. The meter displays t

Pagina 83 - Error Message (error)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 83 Error Message (error) An error message indicates that the calibration or scaling

Pagina 84 - Meter Copy Function (Copy)

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 84 Meter Copy Function (Copy) The Copy function is used to copy (or clone) all the

Pagina 85 - METER OPERATION

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 85 METER OPERATION The meter is capable of accepting any signal from -250 to 250 mV

Pagina 86 - Maximum/Minimum Readings

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 86 Maximum/Minimum Readings The max & min readings (peak & valley) reached

Pagina 87 - TROUBLESHOOTING

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 87 TROUBLESHOOTING Due to the many features and functions of the meter, it’s possib

Pagina 88

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 88 Reset Meter to Factory Defaults When the parameters have been changed in a way t

Pagina 89

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 89 Factory Defaults & User Settings The following table shows the factory setti

Pagina 90

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 9 ISOLATED SENSOR POWER SUPPLY Terminals P+ & P-: 10 VDC or 5 VDC  10%.12/24 V

Pagina 91

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 90 Parameter Display Default Setting User SettingRelay 2 action Act 2 Automatic R

Pagina 92 - Symptom Check/Action

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 91 Parameter Display Default Setting User SettingMinimum output min 1.000 mA Sl

Pagina 93

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 92 Troubleshooting Tips (Including FAULT & ERROR Messages) Symptom Check/Action

Pagina 94

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 93 Alphabetical List of Display Functions & Messages Display Parameter Action/

Pagina 95

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 94 Display Parameter Action/Setting Description Big HL Max/min upper display Assign

Pagina 96

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 95 Display Parameter Action/Setting Description Diag Diagnostics Display parameter

Pagina 97

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 96 Display Parameter Action/Setting Description ICal Internal source calibration En

Pagina 98

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 97 Display Parameter Action/Setting Description No PtS Number of points Set meter f

Pagina 99

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 98 Display Parameter Action/Setting Description RLY 1 Relay 1 Relay 1 setup (1-8) R

Pagina 100 - SFT039 Ver 3.200 & up

Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 99 Display Parameter Action/Setting Description units Units Select the display unit

Comentarios a estos manuales

Sin comentarios